Specifications
Sensing, electrical, mechanical, and safety.
Supply currents are design values.
Sensing#
| Parameter | Value |
|---|---|
| Optical flow sensor | PixArt PMW3901, with lens |
| Flow working distance | 80 mm to infinity |
| Flow field of view | 42° |
| Maximum flow rate | 7.4 rad/s |
| Flow rate | 100 Hz, adjustable from 10 to 100 Hz |
| Rangefinder | ST VL53L4CX time of flight, 940 nm |
| Range | 10 mm to 6 m |
| Range field of view | 18° |
| Range rate | 40 Hz, adjustable from 10 to 50 Hz |
| IMU | Bosch BMI270, 3-axis gyro and 3-axis accelerometer |
| Gyro | ±2000 °/s, sampled at 800 Hz |
| Accelerometer | ±8 g |
The maximum flow rate is 7.4 m/s at 1 m of height, and proportionally more higher up.
Where it works best#
Use it over lit, textured surfaces such as carpet, concrete, grass or patterned tiles. Plain glossy floors, water and darkness give the flow sensor little to follow.
Electrical#
| Parameter | Value |
|---|---|
| Supply voltage | 5 V nominal, 4.0 to 5.5 V, on either port |
| Supply current | 60 mA typical, 135 mA maximum |
| Power protection | Reverse polarity, 0.5 A resettable fuse and ESD clamp on each input |
| Signal protection | ESD protection on CAN and UART |
| Processor | STM32G0B1, Arm Cortex-M0+, 64 MHz |
| UART | 115200 baud, 8N1, 3.3 V logic |
| CAN | Classic CAN, 1 Mbit/s, 500, 250 or 125 kbit/s, detected |
| CAN termination | 120 Ω, switched by a parameter |
Supply no more than 5.5 V to either port.
Mechanical and environmental#
| Parameter | Value |
|---|---|
| Board | 35 x 31 mm, 4-layer, 1.6 mm |
| Enclosure | 42 x 49 x 13.5 mm |
| Operating temperature | 0 to 40 °C |
| Storage temperature | -40 to 85 °C |
Laser safety#
The rangefinder emits invisible 940 nm infrared light. The VL53L4CX is a Class 1 laser device under IEC 60825-1. Do not cover the laser opening or add optics in front of it.
Materials#
Flow Lite complies with EU RoHS (Directive 2011/65/EU, as amended by (EU) 2015/863) with exemptions, and with the Article 33 communication duty of EU REACH. The declaration of compliance, document RL-CMP-FL-001, is available on request.
Handling#
The module contains parts sensitive to electrostatic discharge. Handle it by the enclosure.