Specifications

Sensing, electrical, mechanical, and safety.

Supply currents are design values.

Sensing#

ParameterValue
Optical flow sensorPixArt PMW3901, with lens
Flow working distance80 mm to infinity
Flow field of view42°
Maximum flow rate7.4 rad/s
Flow rate100 Hz, adjustable from 10 to 100 Hz
RangefinderST VL53L4CX time of flight, 940 nm
Range10 mm to 6 m
Range field of view18°
Range rate40 Hz, adjustable from 10 to 50 Hz
IMUBosch BMI270, 3-axis gyro and 3-axis accelerometer
Gyro±2000 °/s, sampled at 800 Hz
Accelerometer±8 g

The maximum flow rate is 7.4 m/s at 1 m of height, and proportionally more higher up.

Where it works best#

Use it over lit, textured surfaces such as carpet, concrete, grass or patterned tiles. Plain glossy floors, water and darkness give the flow sensor little to follow.

Electrical#

ParameterValue
Supply voltage5 V nominal, 4.0 to 5.5 V, on either port
Supply current60 mA typical, 135 mA maximum
Power protectionReverse polarity, 0.5 A resettable fuse and ESD clamp on each input
Signal protectionESD protection on CAN and UART
ProcessorSTM32G0B1, Arm Cortex-M0+, 64 MHz
UART115200 baud, 8N1, 3.3 V logic
CANClassic CAN, 1 Mbit/s, 500, 250 or 125 kbit/s, detected
CAN termination120 Ω, switched by a parameter
Do not exceed 5.5 V

Supply no more than 5.5 V to either port.

Mechanical and environmental#

ParameterValue
Board35 x 31 mm, 4-layer, 1.6 mm
Enclosure42 x 49 x 13.5 mm
Operating temperature0 to 40 °C
Storage temperature-40 to 85 °C

Laser safety#

The rangefinder emits invisible 940 nm infrared light. The VL53L4CX is a Class 1 laser device under IEC 60825-1. Do not cover the laser opening or add optics in front of it.

Materials#

Flow Lite complies with EU RoHS (Directive 2011/65/EU, as amended by (EU) 2015/863) with exemptions, and with the Article 33 communication duty of EU REACH. The declaration of compliance, document RL-CMP-FL-001, is available on request.

Handling#

The module contains parts sensitive to electrostatic discharge. Handle it by the enclosure.