How it works
Why the output is ratiometric, how sensitivity changes with supply, and how to calibrate.
Ratiometric output#
The Texas Instruments DRV5055A2 is a linear analog Hall-effect sensor. Its output is ratiometric, meaning the no-field midpoint voltage and the sensitivity both scale with the supply rail. At zero field, the output sits at VCC / 2. Magnetic flux density passing perpendicular to the top face of the IC moves the output linearly above or below that midpoint.
Why ratiometric matters#
If you power the breakout from the same rail the ADC uses as its reference, the conversion is independent of small supply variations. A 50 mV rail dip becomes a 25 mV midpoint dip, but the ratio between VOUT and VREF is unchanged, so the digital ADC code is unchanged. This is the cleanest way to use the part.
Sensitivity and supply#
| Supply rail | Sensitivity (typical) | Linear range (typical) |
|---|---|---|
| 5.0 V | 50 mV/mT | ±42 mT |
| 3.3 V | 30 mV/mT | ±44 mT |
The A2 variant trades raw resolution for wider linear range, which is useful for tracking rotors or gimbal magnets where field strength varies through several tens of millitesla.
Calibration#
Two-point calibration takes about 30 seconds and removes both part-to-part offset and any small ratiometric error from your supply.
- Zero point: with the board powered and no magnet within 30 cm, sample 256 ADC readings and average them. Store this as
v_zero. - Reference point: place a known magnet at a known distance, or use a calibrated coil at a known field
B_ref. Sample again and store this asv_ref. - Compute scale: calculate
scale = B_ref / (v_ref - v_zero). Save bothv_zeroandscaleto non-volatile storage. - At runtime, calculate
field_mT = (v - v_zero) x scale.
The DRV5055A2 has a small thermal drift in its midpoint. For sub-millitesla precision, re-sample v_zero after the system has been running for at least 60 seconds.