RL-HSB-001 · Sensors · Hall Sensor Breakout

Troubleshooting

Common wiring, saturation, supply, polarity, thermal, and noise symptoms with fixes.

Published May 4, 2026Updated May 8, 2026Reading time ~12 min

01Symptom table#

SymptomLikely causeFix
LED offReversed VCC/GND, no supplyVerify pin order against the silkscreen and re-power.
Output stuck near VCC or 0 VOUT shorted, ADC pin mis-wired, or saturating fieldDisconnect ADC, measure OUT with a multimeter, and remove the magnet.
Reading drifts with supply rippleNon-ratiometric ADC referencePower VCC from the same rail as ADC VREF.
Flips sign vs expectationMagnet polarity or facingFlip the magnet or negate in firmware.
Reading drifts on warm-upThermal offset of ICRe-zero after more than 60 seconds and on every cold start.
Noisy reading at idleLong unshielded cable, switching supplyAdd 100 nF at VCC, shield cable, and oversample 8-16x.

02Fast isolation flow#

Start by measuring VCC and OUT with a multimeter before debugging firmware. With no nearby magnet, OUT should sit near VCC / 2; if it does not, remove the ADC connection and test the breakout alone.